Precise monitoring and registration of mechanical impacts offshore. With internal batteries for automatic function maintenance in the event of power failure.
Registers mechanical influences during the installation and operation of offshore facilities
Measures and analyses directions, strength, time and signal progressions of shock and vibration loads
Highly sensitive and long term stable acceleration sensors
Alarm and operating signalling contacts for the integration of the system in the control technology
Combi-sensor for temperature, air humidity and pressure
Robust and reliable even under extreme climatic conditions
Easy operation, display, alarm function, long operating time
Tamper-proof, multi-level password protection
Internal batteries for automatic function maintenance in the event of power failure
Powerful analysis software
Product description:
Cold weather, storms, high waves, incoming and outgoing vessels are a great burden on the platforms and the electrical equipment of offshore wind parks.
The transformer substation as the centrepiece of the wind park determines the efficiency and reliability of the entire system.
To prevent damage, shocks, vibrations, humidity and temperature must be monitored continuously.
The MONILOG® Offshore Alarm System is specifically designed for these tasks.
For this purpose, the extremely robust data logger ShockDisplay curve plus is used.
Its sensitive sensors monitor humidity and temperature and register real-time mechanical effects with time, duration, direction and strength with minimum and maximum values.
The minimum shock duration is configurable and the registration and alarm thresholds can be set separately for each of the 3 spatial axes.
The number of shocks and other extraordinary loads can be read directly on the data logger.
In the case of limit value overrun, the measured values are transmitted to the control system of the wind park via alarm contacts and operating signalling contacts or life contacts (protection class III).
The system is permanently installed and network-connected.
Internal batteries guarantee the functions in the event of a power failure. All stored values are retained for many years.
The off shore alarm system enables a safe operation sequence through a permanent monitoring and well-processed measurement data, both in the installation and operating phases of transformer substations and in the case of a fault or in the event of a limit value overrun, e.g. by switching off individual components.
The electronics housed in stainless steel housings are installed at the junctions and shocksensitive electrical equipment of the transformer substation platform.
The measurement data show how a shock can spread from a specific location on the offshore platform and can influence the equipment of the system.
With only 4 keys, the data logger is very easy to use.
A USB interface allows fine configuration and data transfer to a PC or laptop.
The measurement data are exactly reproducible, since every activity relevant for the measured value acquisition is registered.
Tampering of the data logger is excluded with a password protection, an internal memory support, checksums and a log of all transactions.
The convenient SYCUR software for preparing and analysing the data is included in the supply.
×
We are looking forward to your message
This MONILOG® RISK LOGGER may interest you
Our recommendation:
MONILOG®
Offshore Alarm System
Precise monitoring and registration of mechanical impacts offshore. With internal batteries for automatic function maintenance in the event of power failure.
Technical data:
Housing
Lockable stainless steel casing, degree of protection IP65, weight 11 kg, dimensions 300 x 300 x 190 mm
Operation and storage conditions
-20 to +40°C, max. 95% relative humidity, non-condensing, special versions for increased requirements
Interfaces
USB 1.1 and RS-232 to link the device to a PC for configuration and data evaluation
Display and operating elements
illuminated display and four function keys, multilingual (DE, EN, FR), password-protected menu
Inclination Measurement
-1 g to +1 g corresponds to -90° to +90° inclination angle, additionally 64 acceleration curves in 3 spatial axes, dynamic range from 0 to 1 Hz, measuring interval adjustable in minutes, recording duration up to 16.000 measuring intervals, self-calibrating in relation to the earth axis
Device certification according to CE, UKCA, RoHS, WEEE; Shock evaluation according to DIN EN 15433-6; Frequency analysis according to DIN EN 13011; Use according to IEEE C 57.150-2012
Programmable parameters
Registration threshold from 5% of the measuring-range end value, min. period of event from 1ms, alarm threshold for shock amplitude, registration threshold for inclination measurement, password, switch on/off protection, time
Shock Measurement
100 shock events with the largest amplitude, three-dimensional, also stored as signal characteristic with 1.024 ms duration at 2 kHz sampling rate, measurement range 5, 10, 20 or 50 g, accuracy ± (2% measuring range and 5% measured value) as well as special versions, frequency range 1 ... 512 Hz (3 dB, digital frequency filter, Bessel 4th order), minimum shock duration and recording level adjustable for each shock direction
Power Supply
2 cells of construction design D (R 20) of type alkaline or lithium, operating time up to 6.000 h
Software
For operating systems Windows Vista/7/8/10, signal analysis graphic and tabular with export functions, frequency analysis according to DIN EN 13011, parametrization of the devices, indication of the status data and active time periods of the device, help function, multilingual (DE, EN, FR)
Fix parameters
Measurement ranges 5, 10, 20, 50 g (special versions on request), filter characteristic of the digital frequency filter up to 512 Hz
Connection requirements
Voltage supply: 90 – 250 V AC or 120 – 250 V DC, 100 mA, 47 … 63 Hz, fuse T 1A L 250 V; connection to N and L polarity-independent; Add. consumer: maximum permissible continuous current 8 A (loop through); Fusing: 6 A l.v.h.b.c. supply line fuse-protection required; Relay contacts: Coil contact insulation voltage 2,5 kVrms.; Switching capacities max. 300 VDC, 250 V AC, 6 A max. AC current rating. Connection cable: 0,25mm² to 4 mm²